Please do take care to read the information thoroughly as it is there to help you understand fault codes and to keep you safe. There are also some help, tips and hints with a lot of the fault codes published here that you usually will not find anywhere else and, as we learn, we add more information so if you can't find what you need please ask in the forums.
Before using this section please understand that fault or error codes are used as a diagnostic aid, they are not a replacement for diagnostic skill on the part of the person repairing the product and are not in any way usually going to point to the precise component that is faulty. All they do is give you an idea of where to start looking for the fault.
Beko Beko American Style Fridge Freezer Error codes
These error code explanations can help you diagnose a problem with your Beko Beko American Style Fridge Freezer.
North London Appliances Repair forums
We add more information as we learn so if you can't find what you need please ask in the Repair forums.
Beko American Style Fridge Freezer Error Codes
E0
Freezer thermistor failure
- Issue:
- Compressor and freezer fan run continuously. Freezer bar-graph display will be off.
- Advice:
-
- Displayed if measured sensor value is open circuit or short circuit
- Resets if the sensor value is correct (not open or short) error is omitted
- Check wiring
- Replace sensor
- Check control module
E1
Freezer defrost sensor failure
- Issue:
- Defrost heater will be switched on for 25 minutes during normal defrost.
- Advice:
-
- Check wiring
- Replace sensor
- Check control module
E3
Fridge thermistor or sensor failure
- Issue:
- Baffle should be opened for 3 minutes and closed for 7 minutes. Fridge bar-graph display will be off. Sensor value is incorrect either open or short.
- Advice:
-
- Check wiring
- Replace sensor
- Replace control module
E4
Defrost heater failure
- Issue:
- If defrost time is equal to the maximum defrost time of 60min. for 3 consecutive defrosts this error is shown. Control runs defrost heater normally.
- Advice:
-
- Check wiring
- Check defrost heater for continuity
- Check module
E8
Icemaker or ice thermistor sensor failure
- Issue:
- Displayed if the module measures the sensor value as open circuit or short circuit. The ice maker will not operate.
- Advice:
-
- Check wiring
- Check sensor
- Check module
E9
Ice machine failure
- Issue:
- If switch does not change as described during initialisation or, while rotating ice machine, if switch position does not change in 1 minute. The icemaker should not operate.
- Advice:
-
- Check wiring
- Check icemaker unit
Arrange a visit from an American style Fridge Freezer engineer
If you do need an engineer to visit your home, help is at hand. We’ll arrange for an engineer near you to call in and fix your appliance, at a time that’s suitable for you.
Book online or give us a call on 0208 226 3633
London Only - Coverage Area | ( Monday - Friday: 8:00 - 20:00 / Saturday: 09:00 - 18:00 )
Warning! To avoid personal injury or death, always unplug the appliance or disconnect the power before attempting any repairs. Always turn off the gas at the source before repairing any gas appliance. Always wear safety glasses when using tools. Keep loose clothing and hair away from any moving parts. Safety is of major importance when performing any service or repair on any electrical appliance. Please, read our disclaimer before proceeding.